Programming the 460i Timer Control for the Autotrol Valve


460ipg3.jpg (116307 bytes)
Click on page thumb nail above to ENLARGE.



TOTAL 460 TIMER PROGRAM RESET


  • 1. Record your Hardness and Capacity settings


  • 2. Disconect power


  • 3. Jumper both pins 'A' and 'B'


  • 4. Reconnect power for at least 10 seconds


  • 5. Disconnect Power


  • 6. Remove Jumpers and return them to 'time' and 'spare'


  • 7. Reconnect power and restore your hardness and capacity settings


  • Result is # days since regeneration and gallons used are '0'
  • Average daily usage is hex 64 or decimal 100 gallons

The REASON you would RESET your timer is IF the unit is Regenerating EVERY NIGHT.
This happens when the "program" is "averaging" your daily use based on the last 30 days,
and you had an unusually HIGH USAGE day during that period.
A Reset should solve this problem.
If not, it may be time to replace the Timer Assembly.


 
460i Timer 12 volt 60 Hz AP1040534 460i Timer 12 volt. 60 Hz - AP1040534
460i Timer ( 12 volt and 60 Hz ) will replace your defective electronic control ( NovRam, 460, 460i ). Requires 12 volt transformer. $199.00     View Details
Quantity
460i Timer w Transformer AP1030000 460i Timer w/ Transformer - AP1030000
Autotrol Electronic Metered Timer Assembly with Transformer for 12 Volt operation from your 120 Volt 60 Hz outlet. Replacement for NovRam, 460, and 460i Timer Assemblies. $219.95     View Details
Quantity
Transformer 120v 60hz to 12vac 1000811 AP1000811 Transformer 120v/60hz to 12vac - 1000811 - AP1000811
Transformer 120v/60hz to 12vac 60 hz used with many Autotrol valves in the U.S.A. PN 1000811 $19.95     View Details
Quantity
440 Replacement Timer Assembly 440i HV w Cord AP440IHV 440 Replacement Timer Assembly 440i HV w/Cord - AP440IHV
Complete 440i for 120 volt 60 hz installations Uses Revised 6 Day Skipper Wheel, and comes ready to plug in. $87.95     View Details
Quantity
 

 Home  ·  Company Information  ·  Contact Us  ·  My Account  ·  Cart  ·  Checkout 
Copyright ® 2009. Please read our Privacy and Returns Policies. 
E-Commerce solution provided by Zoovy.
Softenerparts.com